The term 'albedo' describes the proportion of incident radiation reflected by a system. A perfect reflector would have an albedo of 1, whereas a perfect absorber would have an albedo of 0.
Albedo is sometimes used to describe the proportion of solar radiation reflected by the earth back into space, and this reflectance of solar radiation is also an important property in the built environment. The albedo effect describes this phenomenon on land or indeed at sea.
It has in recent years gained greater attention because of cascade effect or positive feedback loop brought about by a reduction in albedo resulting from the melting of glaciers, ice sheets and ice caps. As bright white and high albedo areas of ice melt due to temperatures rise they are replaced with darker areas of land mass or surface water, these have a low albedo and thus absorb more heat from the sun, which in turn raises the temperature in the local micro-climate which in turn can speed up the melting of ice. The light-coloured surfaces such as ice return a large part of the sunrays back to the atmosphere (high albedo) whereas the dark surfaces such as the ocean absorb the rays from the sun (low albedo).
Indirect solar gain in buildings can be a significant contributor to overheating. Solar radiation absorbed by the envelope of a building can be transmitted through the fabric of the envelope to the interior. In addition, the urban heat island effect, which refers to higher localised temperatures that are experienced in urban environments compared with surrounding green spaces, is primarily caused by the replacement of natural surfaces with hard impervious surfaces that are generally dark and absorb large amounts of solar radiation.
The word ‘albedo’ is derived from the Latin word for whiteness, and very broadly, white-coloured surfaces have a high albedo, and can be effective in minimising solar gain as they tend to be poor absorbers of solar radiation and good emitters (Al-Homoud 2005). The general idea of white washing structures to reject heat has been known since antiquity (Berdahl and Bretz 1997).
However, colour is not always a good indicator of the albedo of a surface as it is determined by reflectance of visible light, rather than other wavelengths of the spectrum (see thermal optical properties for more information). For example commonly used ‘white’ coloured roofing shingles and galvanised steel can reach 35oC and 43oC hotter than air temperatures on a sunny day. Conversely, surfaces painted with red or green acrylic paint may be just 22oC hotter, even though they are not visibly bright (Rosenfeld, Akbari et al. 1995). Galvanised mild steel becomes hot, not due to its low albedo but because of its low emissivity meaning it is slow to cool by re-radiation of long wave infrared radiation (Rosenfeld, Akbari et al. 1995).
Quantitative assessment of the benefits of albedo and thermal emittance is complicated by a number of issues (Suehrcke, Peterson et al. 2008):
- Heat flow across surfaces combines with that due to air temperature differences between the outside and inside.
- Heat flows due to solar absorption and outside-to-inside air temperature differences are variable and influenced by the thermal mass of the building fabric.
- The solar absorbance of a surface will change with time due to dust and ageing.
- If the surface is shaded, the amount of incident sunlight is reduced, which tends to reduce the potential of cool surfaces (Akbari, Menon et al. 2009).
- Effects such as surface roughness and small impurities in materials can lower the albedo of a surface (Berdahl and Bretz 1997).
Despite this, many equations have been derived for quantitatively assessing the effect of albedo and infrared emittance on surface temperatures and internal building temperature (Levinson, Akbari et al. 2007).
Calculations have also been performed to estimate large-scale energy, carbon and cost savings of the widespread implementation of increasing albedo.
It is estimated that pavements and roofs account for 60% of urban surfaces, roofs 20-25% and pavements approximately 40% (Akbari, Menon et al. 2009). Presently these surfaces have relatively low albedo values and high thermal conductivities, typically absorbing and re-radiating around 90% of the total incident solar radiation (Wolf and Lundholm 2008). This contributes to an urban heat island effect that can result in a rise in summer temperatures of 4-7oC (CIBSE 2007; Wolf and Lundholm 2008) in comparison with adjacent vegetated areas.
It is estimated that changing the albedo of roofs and paved surfaces has the potential to increase the albedo of urban areas by 10%. If this was implemented globally across all urban areas, there would be a negative radiative force equivalent to offsetting 44Gt of CO2 emissions (24Gt by roofs, 20Gt by pavements) (Akbari, Menon et al. 2009).
NB the Solar Reflectance Index (SRI), can be considered a better indicator of solar gain as it includes both solar reflectance and emissivity.
NB Whilst increasing roof albedo and infrared emittance can reduce energy consumption in hot climates, it may increase heating-energy consumption in winter months or in cooler climates (Akbari, Levinson et al. 2008).
Global Warming of 1.5 ºC, Glossary, published by the Intergovernmental Panel on Climate Change (IPCC) in 2018, defines solar radiation modification (SRM) as: ‘…the intentional modification of the Earth’s shortwave radiative budget with the aim of reducing warming. Artificial injection of stratospheric aerosols, marine cloud brightening and land surface albedo modification are examples of proposed SRM methods. SRM does not fall within the definitions of mitigation and adaptation (IPCC, 2012b, p. 2). Note that in the literature SRM is also referred to as solar radiation management or albedo enhancement.’
[edit] Related articles on Designing Buildings
- Adaptation
- Climate change science.
- Cool paint.
- Cool roofs.
- Design Summer Year (DSY).
- Emissivity.
- Green roofs.
- G-value.
- Low-e glass.
- Part L.
- Passive building design.
- Shading coefficient.
- Solar gain.
- Solar heat gain coefficient.
- Solar radiation modification.
- Solar reflectance index.
- Thermal comfort.
- Thermal mass
- Thermal optical properties.
- Types of cool roofs.
- Urban heat island effect.
[edit] External references
- Akbari, H., R. Levinson, et al. (2008). "Procedure for measuring the solar reflectance of flat or curved roofing assemblies." Solar Energy 82(7): 648-655.
- Akbari, H., S. Menon, et al. (2009). "Global cooling: increasing world-wide urban albedos to offset CO2." Climatic Change 94(3): 275-286.
- Al-Homoud, D. M. S. (2005). "Performance characteristics and practical applications of common building thermal insulation materials." Building and Environment 40(3): 353-366.
- Berdahl, P. and S. E. Bretz (1997). "Preliminary survey of the solar reflectance of cool roofing materials." Energy and Buildings 25(2): 149-158.
- Levinson, R., H. Akbari, et al. (2007). "Cooler tile-roofed buildings with near-infrared-reflective non-white coatings." Building and Environment 42(7): 2591-2605.
- Rosenfeld, A. H., H. Akbari, et al. (1995). "Mitigation of urban heat islands: materials, utility programs, updates." Energy and Buildings 22(3): 255-265.
- Suehrcke, H., E. L. Peterson, et al. (2008). "Effect of roof solar reflectance on the building heat gain in a hot climate." Energy and Buildings 40(12): 2224-2235.
- Wolf, D. and J. T. Lundholm (2008). "Water uptake in green roof microcosms: Effects of plant species and water availability." Ecological Engineering 33(2): 179-186.
- Yang, J., Q. Yu, et al. (2008). "Quantifying air pollution removal by green roofs in Chicago." Atmospheric Environment 42(31): 7266-7273.
Featured articles and news
Twas the site before Christmas...
A rhyme for the industry and a thankyou to our supporters.
Plumbing and heating systems in schools
New apprentice pay rates coming into effect in the new year
Addressing the impact of recent national minimum wage changes.
EBSSA support for the new industry competence structure
The Engineering and Building Services Skills Authority, in working group 2.
Notes from BSRIA Sustainable Futures briefing
From carbon down to the all important customer: Redefining Retrofit for Net Zero Living.
Principal Designer: A New Opportunity for Architects
ACA launches a Principal Designer Register for architects.
A new government plan for housing and nature recovery
Exploring a new housing and infrastructure nature recovery framework.
Leveraging technology to enhance prospects for students
A case study on the significance of the Autodesk Revit certification.
Fundamental Review of Building Regulations Guidance
Announced during commons debate on the Grenfell Inquiry Phase 2 report.
CIAT responds to the updated National Planning Policy Framework
With key changes in the revised NPPF outlined.
Councils and communities highlighted for delivery of common-sense housing in planning overhaul
As government follows up with mandatory housing targets.
CIOB photographic competition final images revealed
Art of Building produces stunning images for another year.
HSE prosecutes company for putting workers at risk
Roofing company fined and its director sentenced.
Strategic restructure to transform industry competence
EBSSA becomes part of a new industry competence structure.
Major overhaul of planning committees proposed by government
Planning decisions set to be fast-tracked to tackle the housing crisis.
Industry Competence Steering Group restructure
ICSG transitions to the Industry Competence Committee (ICC) under the Building Safety Regulator (BSR).
Principal Contractor Competency Certification Scheme
CIOB PCCCS competence framework for Principal Contractors.
The CIAT Principal Designer register
Issues explained via a series of FAQs.